products

Ultrasonic transducer array: PHC51 and PHC103V and PHL125, etc

Short Description:

Other ultrasonic transducer array that we can provide (Including but not limited to): CX50 C10-3V, C3540, IU22 C5-1, CX50 C5-1, IU22 C5-2, IU22 C6-3, IU22 C8-4V, HD11 C8-4V, C8-5, IU22 L12-5, CX50 L12-5, IU22 L9-3, HD11 S4-2, CX50 C6-2, L12-4, HD11 C5-2, HD3 C5-2,etc.


Product Detail

Product Tags

Ultrasonic transducer accessories PHC51 array

wer
wer
Product name  convex array
Product model  PHC51
Applicable OEM model  C5-1
Frequency  1-5MHz
Service category  Ultrasonic transducer accessories customization
Warranty period  1 year

Delivery time: Arrange delivery as soon as the order is placed. If there is a large demand or special requirements, it will be determined according to the actual situation

Ultrasonic transducer accessories PHC103V array

wer
wer
Product name  Intracavity array
Product model  PHC103V
Applicable OEM model  C10-3V
Frequency  3-10MHz    
Service category  Ultrasonic transducer accessories customization
Warranty period  1 year

Delivery time: Arrange delivery as soon as the order is placed. If there is a large demand or special requirements, it will be determined according to the actual situation

Ultrasonic transducer accessories PHL125 array

wer
er
Product name  Linear array
Product model  PHL125
Applicable OEM model  L12-5
Frequency  5-12MHz             
Service category  Ultrasonic transducer accessories customization
Warranty period  1 year

Delivery time: Arrange delivery as soon as the order is placed. If there is a large demand or special requirements, it will be determined according to the actual situation

How to identify ultrasonic transducer fault in preliminary?

 Malfunctioning sound lens: Bubbles in the sound lens can cause partial black shadows on ultrasonic images; however, pressing down hard on the shadowed area may make it disappear. The damaged of acoustic lens will cause the coupling agent to penetrate into the crystal layer.

Sound head fault: The sound head fault is when the array element (crystal) has some sort of damage, and will appear as a dark channel, blood flow flower, or if it's concentrated in the middle then it will affect normal use.

Shell malfunction: The breaking of the shell will allow the coupling agent to penetrate into the probe, causing oxidation and corrosion of the sound head crystal.

Sheath fault: sheath is the protective layer of the cable, if it break there is a danger of damage to the cables.

Cable fault: The cable is the carrier connecting the sound head and the host system. The fault of the cable will cause the probe to appear dark channel, interference and ghosting.

Circuit fault: will lead to probe error, flaring, no recognition, double image, etc.

Oil sac fault: The oil sac be damaged can result in the leakage of oil, which will cause a black image to form locally.

Three-dimensional/Four-dimensional malfunction: Shows as three-dimensional/four dimensional not working (no image), motor does not work.

We can provide you with all kinds of ultrasonic transducer required accessories, as well as the ultrasonic transducer repair and endoscope repair services.At any time you have any questions, please feel free to contact us, we will answer for you one by one; 

We are looking forward to becoming a long-term and win-win partner with you.

Our team is ready to serve you.